Model GNP-700 with engine Perkins 2806A-E18TAG2 delivers 650 kVA / 565 kW in Prime (PRP) mode and 700 kVA / 609 kW in Standby (ESP) mode. This is a solution for facilities where the generator is part of the operational infrastructure, and the stability of power supply directly affects process continuity.
| Parameter | Value |
|---|---|
| Generator Model | GNP-700 |
| Engine Brand | Perkins |
| Engine Model | 2806A-E18TAG2 |
| Prime Power kVA | 650 kVA |
| Prime Power kW | 565 kW |
| Standby Power kVA | 700 kVA |
| Standby Power kW | 609 kW |
| Parameter | Value |
|---|---|
| Weight | 5220 kg |
| Height | 2200 mm |
| Weight | 1600 mm |
| Length | 3700 mm |
| Fuel Tank | 1016 liters |
| Parameter | Value |
|---|---|
| Weight | 5220 kg |
| Height | 2200 mm |
| Width | 1700 mm |
| Length | 3700 mm |
| Fuel Tank | 1016 liters |
| Parameter | Value |
|---|---|
| Engine Brand | Perkins |
| Engine Model | 2806A-E18TAG2 |
| Maximum Engine Power (Standby) | 609 kW |
| Maximum Engine Power (Prime) | 565 kW |
| Engine Volume | 18.1 liters |
| Engine RPM | 1500 rpm |
| Cylinders and Firing Order | 6 |
| Bore x Stroke | 145x183 |
| Governor Type | Elektronik |
| Electrical System | 24 V |
| Oil Volume | 62 liters |
| Coolant Capacity | 61 liters |
| Fuel Capacity | 1016 liters |
| Fuel Consumption 100% | 132 l/hours |
| Parameter | Value |
|---|---|
| Standby Power | 700 kVa |
| Prime Power | 650 kVa |
| Voltage | 230/400 v |
| Voltage Tolerance | ±1 |
| Frequency | 50 Hz |
| Revolt | 1500 |
| Short Circuit Current | 0.0000 % |
| Insulation | H / IP23 |
| Alternator Capacity | 90 % |
The diesel generator GNP-700 based on the engine Perkins 2806A-E18TAG2 is suitable for facilities where not just emergency backup is required, but reliable coverage of serious operating loads. This format is especially relevant for production sites, processing plants, logistics complexes, commercial infrastructure, hospitals, engineering systems of large buildings, and agricultural facilities with a high dependence on stable power supply.
Power 650 kVA / 565 kW in Prime (PRP) mode and 700 kVA / 609 kW in Standby (ESP) mode makes it possible to keep production lines, pump groups, ventilation, cooling systems, automation, lighting, and other critical equipment running. This is a practical solution for sites where even a short power outage can stop processes, cause losses, disrupt the production cycle, or affect the stability of the facility as a whole.
By its class, GNP-700 belongs to the segment where the generator is considered part of the operational infrastructure. Such a unit is suitable for customers who need a serious level of power, reliable operation under load, and high readiness for long-term автономous operation — without moving into an even heavier high-power class.
The GNP-700 is powered by a 6-cylinder Perkins 2806A-E18TAG2 engine with a displacement of 18,1 liters, designed for stable operation in backup and long-term off-grid power applications.
The combination of the Perkins 2806A-E18TAG2 engine with a power output of 565 kW in Prime (PRP) mode and 609 kW in Standby (ESP) mode makes the generator a reliable solution for facilities with long load cycles. For the user, this means stable equipment operation, predictable performance of the power section, and confidence that the system will be ready to start and operate at full capacity when it is truly needed.
By choosing generator model GNP-700, you will meet your company’s need for stable power supply for many years!!!