Generator GNP-250 with engine Perkins 1506A-E88TAG2 delivers 227 kVA / 204 kW in prime mode (PRP) and 250 kVA / 222 kW in standby mode (ESP) — a solution for facilities where uncompromising power supply reliability is a mandatory requirement.
| Parameter | Value |
|---|---|
| Generator Model | GNP-250 |
| Engine Brand | Perkins |
| Engine Model | 1506A-E88TAG2 |
| Prime Power kVA | 227 kVA |
| Prime Power kW | 204 kW |
| Standby Power kVA | 250 kVA |
| Standby Power kW | 222 kW |
| Parameter | Value |
|---|---|
| Weight | 2040 kg |
| Height | 2010 mm |
| Weight | 1300 mm |
| Length | 3100 mm |
| Fuel Tank | 483 liters |
| Parameter | Value |
|---|---|
| Weight | 2040 kg |
| Height | 2010 mm |
| Width | 1300 mm |
| Length | 3100 mm |
| Fuel Tank | 483 liters |
| Parameter | Value |
|---|---|
| Engine Brand | Perkins |
| Engine Model | 1506A-E88TAG2 |
| Maximum Engine Power (Standby) | 222 kW |
| Maximum Engine Power (Prime) | 204 kW |
| Engine Volume | 8.8 liters |
| Engine RPM | 1500 rpm |
| Cylinders and Firing Order | 6 |
| Bore x Stroke | 112x149 |
| Governor Type | Elektronik |
| Electrical System | 24 V |
| Oil Volume | 41 liters |
| Coolant Capacity | 30 liters |
| Fuel Capacity | 483 liters |
| Fuel Consumption 100% | 48 l/hours |
| Parameter | Value |
|---|---|
| Standby Power | 250 kVa |
| Prime Power | 227 kVa |
| Voltage | 230/400 v |
| Voltage Tolerance | ±1 |
| Frequency | 50 Hz |
| Revolt | 1500 |
| Short Circuit Current | 0.0000 % |
| Insulation | H / IP23 |
| Alternator Capacity | 90 % |
The diesel generator GNP-250 based on the engine Perkins 1506A-E88TAG2 is suitable for facilities that need not just backup power, but reliable coverage of heavy operating loads. This format is ideal for production sites, warehouse complexes, agricultural enterprises, commercial buildings, hotels, service bases, engineering infrastructure facilities, and any sites where power outages directly affect business continuity.
Power 227 kVA / 204 kW in prime mode (PRP) and 250 kVA / 222 kW in standby mode (ESP) makes it possible to keep the key systems of the facility running — process equipment, lighting, pump groups, ventilation, automation, and other power-dependent units. This is a practical solution for enterprises where even a brief power outage leads to financial losses, disruption of production processes, or risks to expensive equipment.
By its class, model GNP-250 belongs to the segment where the generator becomes a full-fledged part of the facility’s working infrastructure, rather than just insurance in the event of an emergency shutdown. It is a well-founded choice for customers who need a serious power level of up to 250 kVA (ESP), a stable power supply, and confidence in long-term reliable operation under high load.
The GNP-250 is based on the Perkins 1506A-E88TAG2 engine, designed for reliable operation in standby and continuous off-grid power applications. The proven design of the Perkins power unit ensures smooth operation under load, stable power delivery, and makes the unit especially suitable for facilities with high requirements for starting reliability, operating stability, and predictable performance during long-term use.
The combination of the power base Perkins 1506A-E88TAG2, the output of 227 kVA / 204 kW in prime mode (PRP) and 250 kVA / 222 kW in standby mode (ESP) makes the generator a convenient solution for constant start readiness and reliable coverage of commercial and industrial loads. For enterprises with uncompromising reliability requirements, this means stable equipment operation, straightforward use, and a high level of confidence in the power unit throughout its service life.
Generator GNP-250 is the choice for those who prioritize the quality of the power base, long engine life, and reliable results under heavy loads. Thanks to the Perkins 1506A-E88TAG2 engine and its industrial configuration, the unit is suitable for scenarios where long автономous operation, resistance to peak and continuous loads, and absolute confidence in the facility’s power supply are especially important.